LFK HP
The LFK HP is a powerful, extremely compact and lightweight two-stage compressor. High pressures up to and above 30 bar and highly
integrated venting circuits are standard features.
LFK MP
The LFK MP is a special LFK model, combining pressure levels of up to 18 bar with high availability of up to and above 35%.
Its outstanding design features are, of course, identical to those of the LFK HP.
LFK EK 13
The LFK EK 13 is a cost-effective, powerful single-piston compressor for pressure levels of up to 15 bar.
It is a device that is ideal for integration into applications at single-axis leveling systems.
LFK Systems
The air suspension compressors are also available as an assembly with individual developed system components such as:
- Bracket mounting kit
- Air intake system
- Pipe system
- Valve block connection
| Compressor type |
LFK11-0.7 (MP) 10 LFK12-0.7 (MP) |
|
LFK17.5-0.7 (MP) |
|
LFK21-0.7 (HP) |
|
LFK21-3 (HP) |
|
LFK EK13-0.7 (MP) |
| Design |
Maintenance-free compressor, dry running meter, with permanently excited DC motor |
|
|
|
|
|
|
|
|
|
|
| Design concept |
two-stage |
|
single-stage |
|
|
|
|
|
|
|
|
|
|
| Electrical data for motor (compressor) |
|
|
|
|
|
|
|
|
|
|
| Operating voltage range |
9-16V DC |
|
|
|
|
|
|
|
|
|
|
| Max. power input |
350W |
|
455W |
|
260W |
|
|
|
|
|
|
|
|
|
|
| Peak starting current (RT) |
lmax <90A for 50ms at 11bar back-pressure |
|
lmax <90A for 50ms at 17bar back-pressure |
|
lmax <110A for 200ms at 17bar back-pressure |
|
lmax <90A for 50ms at 11bar back-pressure |
|
|
|
|
|
|
|
|
|
|
| Max. continous current (RT) |
<27A |
|
<35A |
|
<30A |
|
|
|
|
|
|
|
|
|
|
| Absolute running time |
</=200 sec. |
|
|
|
|
|
|
|
|
|
|
| Relative duty ratio |
20% at 10 min. cycle (RT and 10 bar back-pressure) |
|
25% at 10 min. cycle (RT and 10 bar back-pressure) |
|
18% at 10 min. cycle (RT and 10 bar back-pressure) |
|
|
|
|
|
|
|
|
|
|
| IP degree of protection |
IP6K6/IP6K7K with contacts attached |
|
|
|
|
|
|
|
|
|
|
| Ambiente temperature for operating |
-40°C to 80°C (t<3 min. = 100°C) |
|
|
|
|
|
|
|
|
|
|
| Dimensional and functional stability |
110°C for 1h |
|
|
|
|
|
|
|
|
|
|
| Pneumatics |
|
|
|
|
|
|
|
|
|
|
| Pressure control (integrated) |
11+3bar (12+3bar) |
|
17.5 + 3.5bar |
|
21+3bar |
|
13+3bar |
|
|
|
|
|
|
|
|
|
|
| Remain holding pressure (integrated) |
< 1bar |
|
|
|
|
|
|
|
|
|
|
| Volume intime (RT) |
0-10bar in 1l (reservoir) in approx. 25 sec. or 0-10bar in 3.7l in max. 92 sec. |
|
0-17bar in 1l (reservoir) in approx. 45 sec. or 0-17bar in 3.7l in max. 165 sec. |
|
0-17bar in 1l (reservoir) in approx. 40 sec. or 0-17bar in 3.7l in max. 135 sec. |
|
0-10bar in 1l (reservoir) in approx. 25 sec. or 0-10bar in 3.7l in max. 92 sec. |
|
|
|
|
|
|
|
|
|
|
| Quick Release |
No |
|
Yes |
|
No |
|
|
|
|
|
|
|
|
|
|
| Venting time |
10-5bar in 30 sec. from 3.7l (reservoir) |
|
17-5bar in 7.5 sec. from 10l (reservoir) |
|
10-5bar in 30 sec. from 3.7l (reservoir) |
|
|
|
|
|
|
|
|
|
|
| Other |
|
|
|
|
|
|
|
|
|
|
| Mounting position |
Horizontal motor axle |
|
|
|
|
|
|
|
|
|
|
| Weight |
~3550 gr. |
|
~4000 gr. |
|
~2500 gr. |
|
|
|
|
|
|
|
|
|
|
| Service life (RT) |
240 operating hours (test cycle) |
|
500 operating hours (test cycle) |
|
1000 operating hours (test cycle) |
|
250 operating hours (test cycle) |